Asptraqueal mobile app validation for aspiration
DOI:
https://doi.org/10.17267/2317-3378rec.2022.e3982Keywords:
Endotracheal intubation, Suction, Mobile applications, StomatherapyAbstract
OBJECTIVE: To build and validate a multimedia application on a mobile platform to guide the step-by-step procedure of aspiration of the endotracheal cannula and upper airways. METHODS: The application was validated by 48 professionals using a Delphi technique. For statistical analysis, the Content Validity Index and Cronbach's Alpha index were used. RESULTS: in the first evaluation, the application content items were considered as “inadequate” to “fully designed”. After implementing the recommendations adjustments, the Asptraqueal application content was resubmitted for the second cycle of all items judged “adequate” or “fully adequate”. The Content Validity Index varies between 0.87 and 1.0, this result characterizes the content between excellent and excellent. The average of Cronbach's Alpha coefficient was 0.86, determining good internal consistency of the instrument used to validate the application. CONCLUSION: The Asptraqueal-App was validated for professional evaluation of the area, for the content of the evaluation content between the judges at. The app developed for the endotracheal and airway risk can realize the risk of adverse events.
Downloads
References
Balbino CM, Braz MR, Medeiros JC, Rodrigues LMS, Silvino ZR. Evaluation of aspiration technique on the patient with mechanical ventilation performed by nursing. Rev Enferm UFPE Online [Internet]. 2016;10(Supl. 6):4797-803. Available from: https://periodicos.ufpe.br/revistas/revistaenfermagem/article/viewFile/11258/12880
Donoso MTV, Pertussati E, Simino GPR, Lima LKB, Mattos SS, Silva BVO. Conditions involved in the performance of tracheostomy in intensive care unit patients. Enferm Foco [Internet]. 2021;12(3):469-74. Available from: http://revista.cofen.gov.br/index.php/enfermagem/article/view/3737/1189
Beccaria LM, Doimo TMA, Polletti NAA, Barbosa TP, Silva DC, Werneck AL. Tracheal cuff pressure change before and after the performance of nursing care. Rev Bras Enferm. 2017;70(6):1145-50. https://doi.org/10.1590/0034-7167-2016-0486
Avelino MA, Maunsell R, Valera FCP, Lubianca Neto JF, Schweiger C, Miura CS, et al. First Clinical Consensus and National Recommendations on Tracheostomized Children of the Brazilian Academy of Pediatric Otorhinolaryngology (ABOPe) and Brazilian Society of Pediatrics (SBP). Braz J Otorhinolaryngol. 2017;83(5):498-506. https://doi.org/10.1016/j.bjorl.2017.06.002
Furtado ÉZL, Santos AMR, Moura MEB, Avelino FVSD. Endotracheal aspiration: healthcare team practices in care for critical patients. Rev Enferm UFPE Online [Internet]. 2013;7(esp):6998-7006. Available from: https://periodicos.ufpe.br/revistas/revistaenfermagem/article/viewFile/12369/15112
Gonçalves RL, Tsuzuki LM, Carvalho MG. Endotracheal suctioning in intubated newborns: an integrative literature review. Rev Bras Ter Intensiva [Internet]. 2015;27(3):284-92. Available from: https://www.scielo.br/j/rbti/a/7dzrjPVMWPhpzmBmww3XTYz/?format=pdf&lang=pt
Carmo AFS, Korinfsky JP, Xavier CC, Mendes RNC, Nunes GFO, Silva RM. Nursing in ventilatory assistance: analysis of endotracheal aspiration in the intensive care unit. Rev Enferm UFPE Online [Intetnet]. 2013;7(12):6800-7. Available from: https://periodicos.ufpe.br/revistas/revistaenfermagem/article/downloadSuppFile/12341/9168
González-Samartino M, Delgado-Hito P, Adamuz-Tomás J, Viso Cano MF, Castellà Creus M, Juvé-Udina ME. Accuracy and completeness of records of adverse events through interface terminology. Rev Esc Enferm USP. 2018;52:e03306. https://doi.org/10.1590/S1980-220X2017011203306
Salomé GM, Ferreira LM. Developing a Mobile App for Prevention and Treatment of Pressure Injuries. Advances in Skin & Wound Care. 2018;31(2):1-6. https://doi.org/10.1097/01.asw.0000529693.60680.5e
Cunha JB, Dutra RAA, Salomé GM, Ferreira LM. Computational system applied to mobile technology for evaluation and treatment of wounds. J Nurs UFPE Online. 2018;12(5):1263-72. https://doi.org/10.5205/1981-8963-v12i5a230677p1263-1272-2018
Carvalho MRF, Salomé GM, Ferreira LM. Construction and validation of algorithm for treatment of pressure injury. J Nurs UFPE Online. 2017;11(Suppl. 10):4171-83. Doi: 10.5205/reuol.10712-95194-3-SM.1110sup201722
Salome GM, Rosa GCM. Mobile application to support endotracheal tube and upper airway aspiration. Saúde (Santa Maria). 2020;46(2):e41729. https://doi.org/10.5902/2236583441729.
Salomé GM, Mendonça ARA, Almeida MVT, Miranda FD. A Mobile Application to Guide Healthcare Professionals in the Correct Technique for Personal Protective Equipment Use During the COVID-19 Pandemic. Journal of Coloproctology. 2021; 41(04):383-92. Doi.org/10.1055/s-0041-1739372
Salomé GM, Rocha CA. Mobile application for evaluation, prevention and treatment of dermatitis associated with incontinence. Rev Enferm Contemp. 2020;10(1):1-9. https://doi.org/10.17267/2317-3378rec.v10i1.2963
Cardoso IA, Salomé GM, Miranda FD, Alves JR, Leão JPP, Leão AS, et al. A new APP for prevention and treatment of complications of intestinal peristomal skin. J. Coloproctol. 2020;40(2):120-8. https://doi.org/10.1016/j.jcol.2019.10.011
Pasquali L. Principles of elaboration of psychological scales. Rev Psiq Clin [Internet]. 1998;25(5):206-13. Available from http://www.hcnet.usp.br/ipq/revista/vol25/n5/conc255a.html
Pereira FGF, Rocha DJL, Mel GAA, Jaques RMPL, Formiga LMF. Building and validating a digital application for the teaching of surgical instrumentation. Cogitare Enferm. 2019;24(11):1-11. http://dx.doi.org/10.5380/ce.v24i0.58334
Lopes VJ, Muller F, Souza MAR, Silva IA. Endotracheal suction in patients hospitalized in icu with artificial airway in invasive mechanic ventilation. Rev. enferm. Cent.-Oeste Min. 2018;8:e1973. https://doi.org/10.19175/recom.v8i0.1973
Salomé GM, Cunha AL, Pereira AP, Miranda FD, Alves JR. Educational handbook for healthcare professionals: Preventing complications and treating peristomal skin. J. Coloproctol. 2019; 39(4):332-8. https://doi.org/10.1055/s-0041-1735460
Salomé GM, Mendonça ARA, Almeida MVT, Miranda FD. A Mobile Application to Guide Healthcare Professionals in the Correct Technique for Personal Protective Equipment Use During the COVID-19 Pandemic. J Coloproctol 2021;41(4):383–92. https://doi.org/ 10.1055/s-0041-1739372
Downloads
Published
Issue
Section
License
Copyright (c) 2022 Magela Salomé GMS, Gislaine Cristina Martins Rosa, Jonas isac da rosa
This work is licensed under a Creative Commons Attribution 4.0 International License.